Salient Features:
- 10000 Sq Feet of Area Coverage per
system.
- Can drive upto 20 Torrant Transducers.
MASER CRMS (Centralized Reporting
and Monitoring System) Software supporting:
- Online servicing/maintenance via
web meetings.
- Scheduled or Real Time health status
report generation for Systems Audit.
- Parameter configuration of the controller.
- Two-way Communication between the
controller and the computer.
- MASER RS/ EIA 485 to RS/EIA 232C
converter to transfer the controller
data to the serial port of your computer.
LCD display with on-board controls
for changing the following parameters.
- Wave Speed: Is an indicator
for the number of frequency sweeps
per minute. It can have a maximum
value of 130 and a minimum value of
60. The incremental size is 5 i.e.
65,70,75 and so on.
- Wave Density: Is an indicator
for the number of divisions within
a frequency band. It can have a maximum
value of 100 and a minimum value of
80. The incremental size is 10 i.e.80,90
and 100.
- Frequency Band Time: Is
an indicator of the time for which
the controller would operate in a
pre programmed frequency band. There
are 3 bands available: Band A, Band
B, and Band C. This parameter can
have maximum value of 10 minutes and
a minimum value of 1 minute per band.
Depending upon the time frame set
for each band, the controller will
switch the bands automatically.
- Machine/Controller ID: Is
an indicator of the machine/controller
identification number. It can have
any value within the range of 1 to
255.
- Password Protection: Every
controller is password protected.
To change the parameters mentioned
above you have to key in the password.
The password can be changed if required.
The password can be any 5 digit number.
- Frequency Testing: This feature
will enable the user to test and verify
the frequency that is being transmitted
from the controller to the transducer.
This feature would be particularly
useful during systems audit.
- Transducer Testing: All the
20 transducers can be tested in an
audible range one at a time by using
this feature.
- Provision for restoring all the
parameters to the factory default
setting
- Inbuilt RS/EIA-485 transmission
upto 1.2 kms to BMS room.
- Provision of a termination switch
so that the controller data can be
transferred to the computer and can
be subsequently viewed by installing
MASER CRMS Software.
- Daisy chain protocol for interfacing
64 controllers (nodes)
- Independent Driver for each transducer.
- Independent test facility for each
transducer.
- Torrant Transducer can cover up
to 500 sq. feet of area above false
ceiling, below false ceiling and below
false flooring.
- Torrant Transducer can be interfaced
with MASER STREAME controller.
- Frequency band of > 20Khz and
< 60 Khz is pre tuned for 100 different
frequencies.
- UL and CE approved transformers
for power supply. File No: E305834,
vol No.1, Sec.1.
|